D&B D12 Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Audioverstärker D&B D12 herunter. D&B D12 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Software manual (5.5 EN)

D12 AmplifierSoftware manual (5.5 EN) (Firmware V2.x.x)

Seite 2

Output (Output routing)Settings Id0.01BackInput analogOutput Dual channelSelecting "Output" and pushing the encoder allows the

Seite 3 - Contents

On the right hand side the software version of the selected speakerconfiguration is displayed.A change of the loudspeaker type has to be confirmed. Th

Seite 4

EqualizerEqualizer off SetA 4-band parametric equalizer providing optional Boost/Cut (“PEQ”) orNotch filtering is available for each channel in

Seite 5 - 1. Introduction

Notch function 3 Notch AF 3460 HzQ 25.00 BW 0.04octG -------The following parameters can be e

Seite 6 - 2. The D12 operating software

Impedance ZThe impedance of the loudspeaker(s) presented to the output of theD12, displayed only as a numeric value in ohms. The value is measuredwith

Seite 7

System CheckSystem Check is a powerful and convenient tool to check the conditionof either a single d&b loudspeaker or a complete d&b sound sy

Seite 8 - D12 V 2.xx

Calib. Load MonitoringCancelAPilot Signal LF + 0.0dBuCalib. Load MonitoringOkAFinished LF 9.1 HF 16.0Selecting "Calib

Seite 9 - Input digital

Load Monitoring menuLoad Monitoring ABackMode offDetection Time 99sModeSelecting "Mode" within the "Load Monitoring menu&q

Seite 10 - Source Input A+B

CalibrateNOTICE:Ensure that all components of the system are wired andworking correctly before executing the calibration!Selecting "Calibrate Now

Seite 11 - CPL off

LevelLevel of the frequency generator in dBu covering a 63.5 dB range from–57.5 dB to +6 dB in 0.5 dB steps. The level value corresponds to thelevel a

Seite 12 - G -18.0dB

General InformationD12 AmplifierSoftware manual (Firmware V2.x.x) Version 5.5 EN, 02/2013, D2013.E.05Copyright © 2013 by d&b audiotechnik GmbH

Seite 13 - Power :

AmpPresetD12 amplifiers from firmware version V2.12 provide AmpPresets whichcontain all important user settings of the entire device such as input,out

Seite 14

Name of Preset 9(empty) Ok CancelName of Preset 9MyPresetjklmnopqrstuvwxyzäöüß01MyPresetSTUVWXYZÄÖÜ abcdefghName of P

Seite 15 - Calibrate NowL

RIB/RS232: remote control via RS232 and the SERVICE connectorof the D12. (indicated as "RIB 2" in the main screen)dbCAN: remote control via

Seite 16 - 0.0 ----- 0.0

Edit PasswordMASTERLMNOPQRSTUVWXYZMASTER ABCDEFGHEdit Password1. Selecting "Password" enters the "Edit Password&

Seite 17 - Calibrate Now

OptionsOptionsBackDevice Name DisplayDevice NameD12 X2.0.xx Ok CancelDevice NameStage righStage rightjklmnopqrstuvwxyzäöüß01S

Seite 18 - Load Monitoring

InformationInformationBackTemp.Amp. 35°C 38°CTemp.PS. 36°CHardware t.vvv cnFirmware D12 Xn.n.nnDSP-Ver Xn.nn Xn.nnS/N Z2600nnnnn

Seite 19 - Link A B off

SysErrA numerical value indicating the number of times the D12 has enteredthe error condition "SysErr".RemoteErrA numerical value indicating

Seite 20 - AmpPreset 1

ImpErrLfA numerical value indicating the number of times the D12 has enteredthe error condition "ImpErrLf" due to a Load Monitoring fault.Im

Seite 21 - Remote off

Input MonitoringAccording to the European Standard EN 60849 "ElektroakustischeNotfallwarnsysteme" (equivalent to international standard IEC

Seite 22 - Password

Input Monitoring menuCheck OkInput MonitoringInput A offInput B offMode Analog PilotIn

Seite 23 - LMNOPQRSTUVWXYZ

Contents1. Introduction...51.1 Block diagram of the D12 DSP software...

Seite 24 - Stage right

Power SupplyPower SupplyBackMains 230VFrequency 50HzPower SupplySelecting "Power Supply" and pressing the encoder enters the submenu.M

Seite 25 - Channel B

2.5 Display messages2.5.1 Error messagesError messages can be related either to the device ("Device") or to asingle or both channels of th

Seite 26

Channel Amp. Temp. Warn. ([xx] °C): the temperature of the heat sink isvery high, the air flow should be checked (fan filter) or the load shouldbe red

Seite 27

2.5.4 Further messagesThe following messages are intended for information on the status ofthe D12. They are no error messages.Standby: indicates that

Seite 28

3. D12 Firmware updateNote:A firmware update erases all user settings of the device. The devicename and the log files are kept.The operating software

Seite 29 - Detection Time 1s

4. Remote control & monitoring1...8 1...8 Pin 1 n.c.Pin 2 n.c.Pin 3 n.c.Pin 4 CAN_HPin 5 CAN_LPin 6 n.c.Pin 7 RIB Data +

Seite 30 - Frequency 50Hz

D2013.E.05, 02/2013 © d&b audiotechnik GmbHd&b audiotechnik GmbH, Eugen-Adolff-Str. 134, D-71522 Backnang, Germany, Phone +49-7191-9669-0, Fax

Seite 31

3. D12 Firmware update...343.1 Firmware Installer...

Seite 32

1. IntroductionThis manual describes the structure, access (user interface) and functionsof the firmware of the d&b D12 Amplifier. A detailed desc

Seite 33 - Press A again to reboot

2. The D12 operating software2.1 D12 menu treeThe menu structure of Channel A is shown in detail. The same structureapplies to Channel B.The settings

Seite 34 - 3. D12 Firmware update

2.2 D12 user interfaceD12LEVELPUSH MENUMUTEA BOVLGRISPOVLGRISP[3][4]D12 Stage rightQ7 -3.0dB -3.0dBCUTHFAEQ0.1CSAEQQ-SUB +0.0dBDPLPL100The LCD [

Seite 35

2.3 D12 Boot screenD12 V 2.xxD12d&baudiotechnikFig. 1: D12 Boot screenThe boot procedure takes approximately 4 seconds during which thedevice na

Seite 36

D12 Settings menuSettings Id0.01BackInput analogDual channelCh A Q7Ch B Q-SUBLink A B offRemote offLock Press 2