D6 AmplifierHardware manual (1.9 EN)
3.2. Indicators3.2.1. LC DisplayThe LC Display [4] serves as a user interface and display for allconfiguration settings and status information.The d
4. ConnectionsD6VOLTAGE SEE LABEL~ 50/60 Hz, 1000 WMAINS SUPPLYDIGITAL AES/EBUANALOGOUTBOUTACH ACH BSERVICEREMOTE4.1. Mains connectorWARNING! Pote
4.2. Signal inputs and link outputsNOTICE: To meet the EMC requirements only use shielded cabling andproperly fitted connectors.4.2.1. INPUT A/B and
4.3. Loudspeaker output connectors - OUT A/BWARNING! Potential risk of electric shock.The amplifier's output pins can carry dangerous voltages.-
4.4. REMOTE interfaceThe D6 is fitted with a 2-wire serial remote control interface, (2 x RJ 45[14]) carrying CAN-Bus signals.All pins of both connec
5. Installation and operationNOTICE: Observe the operating conditions and limits as given in thetechnical specifications. Please ensure that ...- no m
5.2. Operation5.2.1. Power consumption and power lossThe power required from the mains supply and the waste heatproduced by the amplifiers power los
5.2.2. Mains supplyThe table below indicates the number of devices per phase conductorwhen full output power is required.Mains supply Number of devic
6. Technical specificationsDisplaysISP A/B...Input Signal Present indicator (green)GR A
OUT A/B...NL4...
Symbols on the equipmentPlease refer to the information in the operatingmanual.WARNING! Dangerous voltage!General InformationD6 AmplifierHardware manu
Operating conditionsTemperature range*...0° C to 40° C / 32° F to 104° F...
7. Manufacturer's declarations7.1. EU declaration of conformity (CE symbol)This declaration applies to- D6 Amplifier, Z2700manufactured by d&
D6 Amplifier, Hardware manual (1.9 EN) Page 22 of 24
D6 Amplifier, Hardware manual (1.9 EN) Page 23 of 24
D2017.EN.01, 02/2014 © d&b audiotechnik GmbHd&b audiotechnik GmbH, Eugen-Adolff-Str. 134, D-71522 Backnang, Germany, Phone +49-7191-9669-0, Fa
Contents1. Introduction...41.1. Intended use...
1. IntroductionThis manual describes the facilities and basic functions of the hardwareof the D6 amplifier. A detailed description of the D6 software
1.3. Maintenance/ServiceDo not open the unit. No user serviceable parts inside. In case of anydamage do not operate the unit under any circumstances.
2. D6 AmplifierFig. 2: D6 Amplifier2.1. D6 based systemsThe D6 Amplifier incorporates:- universal voltage, switch mode power supply with active power
2.3. Power supplyThe switch mode mains power supply permits worldwide applicationwithout the need for mains voltage switching or conversion. The powe
3. Controls and indicators3.1. Controls3.1.1. Power switchThe power switch [1] is a rocker switch type. It does not isolate the unitfrom the mains p
Status indicationThe switch incorporates a green LED indicator which indicates threedifferent states – ON, MUTE and STANDBY.- LED illuminates permanen